Response rate in cardiac resynchronization therapy patients implanted with a left ventricular quadripolar lead and the MultiPoint(TM) Pacing feature activated. QUARTO III.

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • Osca J
  • Francisco-Pascual J
  • Martínez-Basterra J
  • Reis H
  • Oliveira M
  • Campos B
  • Balaguer J
  • Rubio J
  • Pavón-Jiménez R
  • Hernández J
  • Ormaetxe JM
  • Zamorano JL
  • Santamaría P
  • Alzueta J

Grupos de Investigación

Abstract

BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. It has been suggested that multipoint left ventricle pacing (MPP) would increase the response rate. AIM: To assess the CRT response rate at 6 months in patients implanted with a CRT device with the MPP feature activated early after the implant. METHODS: This was a multicentre, prospective, open-label and non-randomized study. The primary endpoint was response to biventricular pacing defined as >15% relative reduction in left ventricular end-systolic volume (LVESV) comparing echocardiography measurements performed at baseline and 6 months by a core laboratory. Among secondary endpoints the combined endpoint of mortality or all-cause hospitalizations was evaluated. Primary study endpoint and clinical outcomes were compared to a Quarto II control cohort. RESULTS: 105 patients were included. The response rate was 64.6% (97.5% lower confidence bound 53%). Mean relative reduction in LVESV was 25.3% and mean absolute increase in LVEF was 9.4%. The subjects with device programmed using anatomical approach showed a trend toward higher responder rate than those using the electrical approach (72% vs. 61.1%, p= 0.32). Finally, the combined incidence of mortality and or all-cause hospitalizations at 6 month was 12.4%. CONCLUSIONS: Early activation of MPP was not associated to an advantage increasing echocardiography responders to CRT at 6 months of follow up. Nevertheless, patients programmed using widest pacing cathodes had a numerically higher responder rate. Finally, early activation of MPP was associated to a low incidence of clinical endpoints at 6 months of follow-up.

This article is protected by copyright. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0014-2972, 1365-2362

EUROPEAN JOURNAL OF CLINICAL INVESTIGATION  WILEY

Tipo:
Article
Páginas:
-
PubMed:
36504276
Enlace a otro recurso:
onlinelibrary.wiley.com

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Cardiac Resynchronization Therapy.; Dyssynchrony.; Heart Failure; Multipoint pacing.; Outcomes.

Cita

Compartir