EUS-guided gastroenterostomy versus duodenal self-expandable metal stent for malignant gastric outlet obstruction: Results from a nationwide multicenter retrospective study.

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • Sánchez-Aldehuelo R
  • Subtil Iñigo JC
  • Gornals J
  • Guarner-Argente C
  • Ortega AR
  • Herce SP
  • Rodríguez de Santiago E
  • Bazaga S
  • Juzgado D
  • González-Panizo F
  • Albillos A
  • Vázquez-Sequeiros E

Grupos de Investigación

Abstract

BACKGROUND AND AIMS: Traditionally, palliative treatment of malignant gastric outlet obstruction (GOO) has been surgical. Nevertheless, it associates significant morbidity and mortality rates. Endoscopic placement of a duodenal self-expandable metal stent (D-SEMS) has been proven to be successful for this indication in the short-term. However, D-SEMS are likely to malfunction over time. EUS-guided gastroenterostomy (EUS-GE) may help overcome these limitations. We aimed to evaluate stent failure-free survival at 3 months. METHODS: A nationwide multicenter, observational study of D-SEMS and EUS-GE procedures for patients with malignant GOO was conducted at 7 academic centers (January 2015-June 2020). Stent failure-free survival at 1, 3 and 6 months, technical and clinical success, adverse events and patient survival were evaluated in both groups and compared. RESULTS: 97 patients were included in the D-SEMS group and 79 in the EUS-GE group. Pancreatic cancer was the main underlying malignancy in 53.4%. No statistically significant differences regarding technical (92.8% vs 93.7%) or clinical success (83.5% vs 92.4%) were found. Adverse events rate did not differ between groups (10.3% vs 10.1%) though two events in the EUS-GE group required surgical management. Patients in the EUS-GE had improved stent patency when compared with those patients in the D-SEMS Group at 3 months (92.23% vs 80.6%,) adjusted HR: 0.37; p=0.033. CONCLUSIONS: EUS-GE seems to have improved patency outcomes when compared with D-SEMS for palliative treatment of malignant GOO. Prospective trials are needed to fully compare their efficacy and adverse event profile.

Copyright © 2022 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0016-5107, 1097-6779

GASTROINTESTINAL ENDOSCOPY  MOSBY-ELSEVIER

Tipo:
Article
Páginas:
1012-
PubMed:
35870508

Citas Recibidas en Web of Science: 39

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Endoscopic ultrasound; Gastric outlet obstruction; Gastroenterostomy; Self expandable metallic stent

Cita

Compartir