Robust estimation of infant feeding indicators by data quality assessment of longitudinal electronic health records from birth up to 18 months of life

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • Garcia-de-Leon-Chocano, R
  • Saez, C
  • Munoz-Soler, V
  • Garcia-de-Leon-Gonzalez, R
  • Garcia-Gomez, JM

Grupos de Investigación

Abstract

Background and objective: The Baby-Friendly Hospital Initiative (BFHI) is an international strategy aimed at improving breastfeeding practices in health care services. Regular monitoring of indicators is key for BFHI implementation and maintenance. Currently, routine data collected from electronic health records (EHR) is an excellent source for infant feeding monitoring, however data quality (DQ) assessment should be undertaken. The aim of this research is to enable robust estimations of infant feeding indicators through DQ assessment of routine EHR data. Materials and methods: We use the longitudinal series of healthcare contacts belonging to 6427 children born from 2009 to 2018 in the Health Area V of Murcia (Spain). Longitudinal data came from EHR at hospital discharge and community infant health reviews up to 18 months. The data of each healthcare contact contained a 24-h recall of infant feeding. We perform a DQ process in three phases: (1) an assessment of each-single-contact and the definition of their infant feeding status; (2) a longitudinal DQ assessment of completeness and consistency of the series of contacts to obtain meta-information that guides the duration calculus, for each case, of the different types of breastfeeding: exclusive breastfeeding (EBF), full breastfeeding (FBF) and any breastfeeding (ABF); and finally (3) a robust estimation of indicators and description of DQ of each indicator. Results: We found deficiencies of DQ in 30.42% of single contacts for EBF, 19.02% for FBF and 22.50% for ABF that were used to establish the infant feeding status. However, after longitudinal DQ assessment, we obtained valid and reliable data rates for most indicators such as "median duration of breastfeeding" nearly 90%, both for FBF and ABF, not so for EBF. Conclusions: Despite the DQ deficiencies found in raw data, the DQ assurance approach by indicators proposed in this work, allowed us to obtain a robust estimation of indicators with a significant percentage of subjects with valid information for ABF and FBF monitoring. The estimations were consistent with results previously published. The methodology provided with this study allows a continuous and reliable population monitoring of infant feeding indicators of BFHI from routine EHR data. (c) 2021 Published by Elsevier B.V.

Copyright © 2021. Published by Elsevier B.V.

Datos de la publicación

ISSN/ISSNe:
0169-2607, 1872-7565

Computer Methods and Programs in Biomedicine  ELSEVIER IRELAND LTD

Tipo:
Article
Páginas:
106147-106147
PubMed:
34020376
Enlace a otro recurso:
www.sciencedirect.com

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Electronic health record; Data quality; Indicator; Monitoring; Baby-friendly hospital initiative; Infant feeding

Cita

Compartir