10-Year Follow-Up of Patients With Everolimus-Eluting Versus Bare-Metal Stents After ST-Segment Elevation Myocardial Infarction

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

  • Vicente Mainar Tello

    Autor

  • Pascual Bordes Siscar

    Autor

Participantes ajenos a ISABIAL

  • Brugaletta, S
  • Gomez-Lara, J
  • Ortega-Paz, L
  • Jimenez-Diaz, V
  • Jimenez, M
  • Jimenez-Quevedo, P
  • Diletti, R
  • Campo, G
  • Silvestro, A
  • Maristany, J
  • Flores, X
  • Oyarzabal, L
  • De Miguel-Castro, A
  • Iniguez, A
  • Serra, A
  • Nombela-Franco, L
  • Ielasi, A
  • Tespili, M
  • Lenzen, M
  • Gonzalo, N
  • Tebaldi, M
  • Biscaglia, S
  • Rodriguez-Arias, JJ
  • Al-Shaibani, S
  • Arevalos, V
  • Romaguera, R
  • Gomez-Hospital, JA
  • Serruys, PW
  • Sabate, M

Grupos de Investigación

Abstract

BACKGROUND Outcomes data for a durable-polymer everolimus-eluting stent (EES) at extended long-term follow-up in patients with ST-segment elevation myocardial infarction (STEMI) are unknown. OBJECTIVES The aim of this study was to assess the 10-year outcomes of patients enrolled in the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction) trial. METHODS The EXAMINATION-EXTEND (10-Years Follow-Up of the EXAMINATION Trial) study is an investigator-driven 10-year follow-up of the EXAMINATION trial, which randomly assigned 1,498 patients with STEMI in a 1:1 ratio to receive either EES (n = 751) or bare-metal stents (n = 747). The primary endpoint was a patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization. Secondary endpoints included a device-oriented composite endpoint of cardiac death, target vessel myocardial infarction, or target lesion revascularization; the individual components of the combined endpoints; and stent thrombosis. RESULTS Complete 10-year clinical follow-up was obtained in 94.5% of the EES group and 95.9% of the bare-metal stent group. Rates of the patient-oriented composite endpoint and device-oriented composite endpoint were significantly reduced in the EES group (32.4% vs. 38.0% [hazard ratio: 0.81; 95% confidence interval: 0.68 to 0.96; p = 0.013] and 13.6% vs. 18.4% [hazard ratio: 0.72; 95% confidence interval: 0.55 to 0.93; p = 0.012], respectively), driven mainly by target lesion revascularization (5.7% vs. 8.8%; p = 0.018). The rate of definite stent thrombosis was similar in both groups (2.2% vs. 2.5%; p = 0.590). No differences were found between the groups in terms of target lesion revascularization (1.4% vs. 1.3%; p = 0.963) and definite or probable stent thrombosis (0.6% vs. 0.4%; p = 0.703) between 5 and 10 years. CONCLUSIONS At 10-year follow-up, EES demonstrated confirmed superiority in combined patient- and device-oriented composite endpoints compared with bare-metal stents in patients with STEMI requiring primary percutaneous coronary intervention. Between 5- and 10-year follow-up, a low incidence of adverse cardiovascular events related to device failure was found in both groups. (10-Years Follow-Up of the EXAMINATION Trial; NCT04462315) (c) 2021 by the American College of Cardiology Foundation.

Copyright © 2021 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0735-1097, 1558-3597

JACC-Journal of the American College of Cardiology  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1165-1178
PubMed:
33663733
Enlace a otro recurso:
reader.elsevier.com

Citas Recibidas en Web of Science: 68

Documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • everolimus; randomized controlled trial; stent; stent thrombosis; ST-segment elevation myocardial infarction

Cita

Compartir