Impact of operators experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry(2)
Fecha de publicación:
Fecha Ahead of Print:
Autores de ISABIAL
Participantes ajenos a ISABIAL
- Cruz-Gonzalez, I
- Saura, FT
- Trejo-Velasco, B
- Diaz, JAF
- Molina, RF
- Del Valle-Fernandez, R
- Terribas, GM
- Sanchez, DM
- Lopez-Minguez, JR
- Gomez-Blazquez, I
- Pena, JCS
- Botas, J
- Lorenzo, PM
- Palazuelos, J
- Rincon, RA
- Mohandes, M
- Entem, FJR
- Marti, G
- Valero, E
- Gutierrez, H
- Amat-Santos, IJ
- Nombela-Franco, L
- Salinas, P
- Teruel, L
- Gomez-Hospital, JA
- Arzamendi, D
- Sanabria, MT
- Perez, GC
- Pruano, DC
- de Prado, AP
- Gonzalez, TB
- Arroyo-Ucar, E
- Estevez-Loureiro, R
- Caneiro-Queija, B
Grupos de Investigación
Abstract
Background: The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. Methods: Prospective, multicenter, "real-world" registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed <= 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. Results: 359 patients [mean age 75.5 (SD8.1), CHA(2)DS(2)-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the center's previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. Conclusions: The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operator's experience with its previous device iteration or the number of Watchman FLX devices implanted.
© 2021 Published by Elsevier B.V.
Datos de la publicación
- ISSN/ISSNe:
- 2352-9067, 2352-9067
- Tipo:
- Article
- Páginas:
- 100941-100941
- PubMed:
- 35024431
IJC Heart & Vasculature ELSEVIER IRELAND LTD
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- Atrial fibrillation; Left atrial appendage occlusion; Devices; Outcomes
Proyectos y Estudios Clínicos
Cita
Cruz Gonzalez I, Saura FT, Trejo Velasco B, Diaz J, Molina RF, Del Valle Fernandez R, Terribas GM et al. Impact of operators experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry(2). IJC Heart Vasc. 01 febrero 2022;38100941. https://doi.org/10.1016/j.ijcha.2021.100941.
Portal de investigación