Abstract

Objectives. To determine whether the volume of monosodium urate (MSU) crystal deposition measured with dual-energy CT (DECT) is predictive of short-term mortality and development of cardiovascular comorbidities and diabetes mellitus. Methods. Patients with a diagnosis of gout having had baseline DECT scans of their knees and feet to measure the volume of MSU crystal deposition were included to undergo a follow-up visit. Risk factors for mortality and a composite variable (onset of any cardio-metabolic event) were examined using multivariable Cox models. Results. A total of 128 patients aged 66.1 (14.0) years with gout durations of 11.4 (10.4) years were included; most were naive of urate lowering therapy (61.7%), with a follow-up visit at 24 (12, 36) months. Baseline serum urate (SU) level was 7.44 (2.29) mg/dl and DECT volume of MSU crystals was 0.2 (0, 0.9) cm(3). A total of 14 patients died during follow-up, 6/14 from a cardiovascular cause, and 17 patients presented a new cardio-metabolic comorbidity. Factors associated with mortality risk were baseline DECT volume of MSU crystals [hazard ratio (HR) 1.02, 95% CI: 1.002, 1.03] and baseline SU level (HR 1.04, 95% CI: 1.003, 1.06). DECT volume of MSU crystals was the only factor associated with the onset of cardio-metabolic comorbidities with a HR of 1.014 (95% CI: 1.001, 1.03). Conclusions. Volume of MSU crystals measured with DECT is a biomarker for the risk of developing new cardio-metabolic diseases and for all-cause mortality.

© The Author(s) 2021. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Datos de la publicación

ISSN/ISSNe:
1462-0324, 1462-0332

RHEUMATOLOGY  OXFORD UNIV PRESS

Tipo:
Article
Páginas:
4855-4860
PubMed:
33410483
Enlace a otro recurso:
academic.oup.com

Citas Recibidas en Web of Science: 36

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • gout; dual-energy computed tomography; monosodium urate crystal; cardiovascular events; mortality

Cita

Compartir