Endoscopic ultrasound-guided drainage of pancreatic walled-off necrosis using 20-mm versus 15-mm lumen-apposing metal stents: an international, multicenter, case-matched study

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • Parsa, N
  • Nieto, JM
  • Powers, P
  • Mitsuhashi, S
  • Abdelqader, A
  • Hadzinakos, G
  • Anderloni, AA
  • Fugazza, A
  • James, TW
  • Arlt, A
  • Ellrichmann, M
  • Trindade, AJ
  • Stevens, TK
  • Chahal, P
  • Shah, SL
  • Messallam, AA
  • Lang, GR
  • Fejleh, MP
  • Benias, PC
  • Sejpal, DV
  • Jones, J
  • Mir, FF
  • Meybodi, MA
  • Ichkhanian, Y
  • Vosoughi, K
  • Novikov, AA
  • Irani, SS
  • Pawa, R
  • Ahmed, AM
  • Sedarat, A
  • Hsueh, WL
  • Hampe, J
  • Sharaiha, RZ
  • Berzin, TM
  • Willingham, FF
  • Kushnir, VM
  • Gutierrez, OBI
  • Ngamruengphong, S
  • Huggett, MT
  • Baron, TH
  • Repici, A
  • Adler, DG
  • Nasr, JT
  • Kowalski, TE
  • Kumbhari, V
  • Singh, VK
  • Khashab, MA

Grupos de Investigación

Abstract

Backgrounds Endoscopic ultrasound (EUS)-guided placement of lumen-apposing metal stents (LAMSs) has gained popularity for the treatment of pancreatic walled-off necrosis (WON). We compared the 20-mm and 15-mm LAMSs for the treatment of symptomatic WON in terms of clinical success and adverse events. Methods We conducted a retrospective, case-matched study of 306 adults at 22 tertiary centers from 04/2014 to 10/2018. A total of 102 patients with symptomatic WON who underwent drainage with 20-mm LAMS (cases) and 204 patients who underwent drainage with 15-mm LAMS (controls) were matched by age, sex, and drainage approach. Conditional logistic regression analysis was performed to compare clinical success (resolution of WON on follow-up imaging without reintervention) and adverse events (according to American Society for Gastrointestinal Endoscopy criteria). Results Clinical success was achieved in 92.2 % of patients with 20-mm LAMS and 91.7 % of patients with 15-mm LAMS (odds ratio 0.92; P = 0.91). Patients with 20-mm LAMS underwent fewer direct endoscopic necrosectomy (DEN) sessions (mean 1.3 vs. 2.1; P < 0.001), despite having larger WON collections (transverse axis 118.2 vs. 101.9 mm, P = 0.003; anteroposterior axis 95.9 vs. 80.1 mm, P = 0.01). There was no difference in overall adverse events (21.6 % vs. 15.2 %; P = 0.72) and bleeding events (4.9 % vs. 3.4 %; P = 0.54) between the 20-mm and 15-mm LAMS groups, respectively. Conclusions The 20-mm LAMS showed comparable clinical success and safety profile to the 15-mm LAMS, with the need for fewer DEN sessions for WON resolution.

Datos de la publicación

ISSN/ISSNe:
0013-726X, 1438-8812

ENDOSCOPY  GEORG THIEME VERLAG KG

Tipo:
Article
Páginas:
211-219
PubMed:
32000275
Enlace a otro recurso:
www.thieme-connect.de

Citas Recibidas en Web of Science: 54

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Cita

Compartir