Negative screening of Fabry disease in patients with conduction disorders requiring a pacemaker.

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • López-Sainz Á
  • Ripoll-Vera T
  • Espinosa MA
  • Barriales-Villa R
  • Navarro M
  • Limeres J
  • Domingo D
  • Kasper DC
  • Garcia-Pavia P

Grupos de Investigación

Abstract

Identification of Fabry disease (FD) in cardiac patients has been restricted so far to patients with left ventricular hypertrophy. Conduction problems are frequent in FD and could precede other manifestations, offering a possible earlier diagnosis.We studied the prevalence of FD in 188 patients < 70 years with conduction problems requiring pacemaker implantation. Although classical manifestations of FD were not rare, no patient with FD was identified. Screening efforts should not be conducted in this population.

Datos de la publicación

ISSN/ISSNe:
1750-1172, 1750-1172

Orphanet Journal of Rare Diseases  BMC

Tipo:
Letter
Páginas:
170-170
PubMed:
31286959

Citas Recibidas en Web of Science: 7

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Conduction disease, Fabry disease, Left ventricular hypertrophy, Pacemaker, Screening