Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials
Autores de ISABIAL
Participantes ajenos a ISABIAL
- Alfonso, Fernando
- Perez-Vizcayno, Maria Jose
- del Blanco, Bruno Garcia
- Garcia-Touchard, Arturo
- Lopez-Minguez, Jose-Ramon
- Masotti, Monica
- Zueco, Javier
- Melgares, Rafael
- Moreno, Raul
- Dominguez, Antonio
- Sanchis, Juan
- Bethencourt, Armando
- Moreu, Jose
- Cequier, Angel
- Marti, Vicens
- Otaegui, Imanol
- Bastante, Teresa
- Gonzalo, Nieves
- Jimenez-Quevedo, Pilar
- Cardenas, Alberto
- Fernandez, Cristina
- Spanish Soc Cardiology
Grupos de Investigación
Abstract
Background-Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. Methods and Results-A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22 +/- 0.5 versus 2.38 +/- 0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03 +/- 0.7 versus 2.36 +/- 0.6 mm, P<0.001) and diameter stenosis (23 +/- 22 versus 13 +/- 17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at followup remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. Conclusions-This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DESISR than in those with bare-metal stent ISR.
Datos de la publicación
- ISSN/ISSNe:
- 1941-7640, 1941-7632
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 27412868
Circulation-Cardiovascular Interventions LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 19
Documentos
- No hay documentos
Filiaciones
Cita
Alfonso F, Perez Vizcayno MJ, del Blanco BG, Garcia Touchard A, Lopez Minguez J, Masotti M, Zueco J et al. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials. Circ.-Cardiovasc. Interv. 01 julio 2016;9(7):e003479. https://doi.org/10.1161/CIRCINTERVENTIONS.115.003479.
Portal de investigación