Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials

Fecha de publicación:

Autores de ISABIAL

  • Vicente Mainar Tello

    Autor

Participantes ajenos a ISABIAL

  • Alfonso, Fernando
  • Perez-Vizcayno, Maria Jose
  • del Blanco, Bruno Garcia
  • Garcia-Touchard, Arturo
  • Lopez-Minguez, Jose-Ramon
  • Masotti, Monica
  • Zueco, Javier
  • Melgares, Rafael
  • Moreno, Raul
  • Dominguez, Antonio
  • Sanchis, Juan
  • Bethencourt, Armando
  • Moreu, Jose
  • Cequier, Angel
  • Marti, Vicens
  • Otaegui, Imanol
  • Bastante, Teresa
  • Gonzalo, Nieves
  • Jimenez-Quevedo, Pilar
  • Cardenas, Alberto
  • Fernandez, Cristina
  • Spanish Soc Cardiology

Grupos de Investigación

Abstract

Background-Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. Methods and Results-A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22 +/- 0.5 versus 2.38 +/- 0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03 +/- 0.7 versus 2.36 +/- 0.6 mm, P<0.001) and diameter stenosis (23 +/- 22 versus 13 +/- 17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at followup remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. Conclusions-This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DESISR than in those with bare-metal stent ISR.

Datos de la publicación

ISSN/ISSNe:
1941-7640, 1941-7632

Circulation-Cardiovascular Interventions  LIPPINCOTT WILLIAMS & WILKINS

Tipo:
Article
Páginas:
-
PubMed:
27412868

Citas Recibidas en Web of Science: 19

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Cita

Compartir