EUS-guided gastroenterostomy using a parallel enteric tube for luminal distension: Prospective multicenter procedural standardization (with video)

Fecha de publicación: Fecha Ahead of Print:

Autores de ISABIAL

Participantes ajenos a ISABIAL

  • Chavarría, C
  • Martín-Alvarez, V
  • Subtil, JC
  • Garcia-Alonso, FJ
  • Vila, JJ
  • Bea, VB
  • de la Serna-higuera, C
  • Perez-Miranda, M

Grupos de Investigación

Abstract

Background and ObjectivesThe EUS-guided gastroenterostomy (EUS-GE) technique remains nonstandardized. We primarily aimed at standardizing parallel enteric tube (PET)-assisted EUS-GE, secondarily assessing reproducibility and outcomes. MethodsThis prospective multicenter study included consecutive adult patients with unresectable malignant gastric outlet obstruction undergoing primary EUS-GE between August 2019 and April 2021. Hierarchical task analysis predefined procedural steps into tasks and subtasks. Subtasks were further categorized into essential (performed in all centers and in more than 85% of the procedures) or optional. Subtask methodology was considered established if performed similarly in all centers or variable if not. Procedure times, injected fluid volume, accessories, adverse events (AEs), and outcomes were recorded. ResultsSeven endoscopists performed EUS-GE in 65 patients (50.8% male, median [interquartile range] age 77.5 [65.7-86.5] years). EUS-GE was categorized into 4 tasks (enteric tube placement, endoscope exchange, small bowel distention plus targeting, lumen-apposing metal stent placement) and 10 subtasks (7 essential, 3 optional). Five essential subtasks involved an established methodology (guidewire and PET placement, endoscope exchange, delivery system insertion, and lumen-apposing metal stent deployment).Technical and clinical success rates were 98.5% and 83.3%, respectively. AEs occurred in 10 (15.4%) patients. Success and AE rates were not different between expert and nonexperts. Procedure time was longer (35 [30.6-43.7] vs. 21.8 [16.4-29.5] minutes, P < 0.001) and injected fluid volume higher (510 [439-870] vs. 415 [255-480] mL, P = 0.01) in nonexperts.ResultsSeven endoscopists performed EUS-GE in 65 patients (50.8% male, median [interquartile range] age 77.5 [65.7-86.5] years). EUS-GE was categorized into 4 tasks (enteric tube placement, endoscope exchange, small bowel distention plus targeting, lumen-apposing metal stent placement) and 10 subtasks (7 essential, 3 optional). Five essential subtasks involved an established methodology (guidewire and PET placement, endoscope exchange, delivery system insertion, and lumen-apposing metal stent deployment).Technical and clinical success rates were 98.5% and 83.3%, respectively. AEs occurred in 10 (15.4%) patients. Success and AE rates were not different between expert and nonexperts. Procedure time was longer (35 [30.6-43.7] vs. 21.8 [16.4-29.5] minutes, P < 0.001) and injected fluid volume higher (510 [439-870] vs. 415 [255-480] mL, P = 0.01) in nonexperts. ConclusionsPET-assisted EUS-GE was standardized, identifying its key steps and technique variants. PET-assisted EUS-GE appears to be a reproducible procedure among advanced endoscopists with different levels of experience.(ClinicalTrials identification no. NCT04660695).ConclusionsPET-assisted EUS-GE was standardized, identifying its key steps and technique variants. PET-assisted EUS-GE appears to be a reproducible procedure among advanced endoscopists with different levels of experience.(ClinicalTrials identification no. NCT04660695).

t © 2025 The Author(s)

Datos de la publicación

ISSN/ISSNe:
2303-9027, 2226-7190

Endoscopic Ultrasound  LIPPINCOTT WILLIAMS & WILKINS

Tipo:
Article
Páginas:
129-136
PubMed:
41584027
Enlace a otro recurso:
journals.lww.com

Citas Recibidas en Web of Science: 2

Documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • EUS-guided gastroenterostomy (EUS-GE); Gastric outlet obstruction (GOO); Lumen-apposing metal stent (LAMS); Parallel enteric tube (PET)

Cita

Compartir