Failure of the new underexpansion criteria to predict outcomes after ACURATE neo2 valve implantation: results from an independent multicenter registry.
Autores de ISABIAL
Participantes ajenos a ISABIAL
- Pan M
- González-Manzanares R
- Blas SG
- Torralba EI
- Molina AA
- de la Torre-Hernández JM
- Tébar D
- Gallo I
- Rivadulla C
- Saura FT
- Menchero AEG
- Díaz JF
- Fernández GV
- Vila-García J
- Moreno R
- Sanchis J
- Ojeda S
Grupos de Investigación
Abstract
INTRODUCTION AND OBJECTIVES: Suboptimal outcomes with the ACURATE neo2 valve have been attributed to valve frame underexpansion, reported in approximately 20% of cases according to 3 recently proposed angiographic criteria. We aimed to validate these criteria in an independent registry with a 2-year follow-up. METHODS: This registry included 696 patients with severe aortic stenosis treated with the ACURATE neo2 valve at 7 experienced centers. Underexpansion was defined as the presence of at least 1 of the 3 criteria; the boundary box method was also applied to assess postparallelism. The primary endpoint was a composite of all-cause mortality, stroke, or heart failure hospitalization at 2 years. RESULTS: The mean age was 81 ± 5.8 years. Based on the 3-criteria method, underexpansion was identified in 154 patients (22%). There were no significant differences in the primary endpoint between the 2 groups. The cumulative incidence of the composite outcome was 13.7% vs 11.0% at 1 year and 21.0% vs 17.4% at 2 years for the underexpanded and expanded groups, respectively (P = .535). Similarly, no differences were observed with the boundary box method. On multivariable analysis, underexpansion was not independently associated with the primary endpoint (HR, 1.15; 95%CI, 0.73-1.80, P = .537). The only variables significantly associated with major adverse events at 2-years were atrial fibrillation, diabetes mellitus, and reduced glomerular filtration rate. CONCLUSIONS: The presence of at least 1 angiographic underexpansion criterion after ACURATE neo2 implantation did not predict adverse outcomes at follow-up.
Copyright © 2025 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Datos de la publicación
Documentos
- No hay documentos
Filiaciones
Keywords
- ACURATE neo2; Aortic stenosis; Estenosis aórtica; Infraexpansión; TAVI; Underexpansion
Cita
Pan M, González Manzanares R, Blas SG, Ruiz Nodar JM, Torralba EI, Molina AA, de la Torre Hernández JM et al. Failure of the new underexpansion criteria to predict outcomes after ACURATE neo2 valve implantation: results from an independent multicenter registry. Rev. Esp. Cardiol. 01 mayo 2026;79(5):https://doi.org/10.1016/j.rec.2025.09.007.
Portal de investigación