Could optical coherence tomography detect monosodium urate crystal deposition at artery walls? An exploratory, phantom-based study
Fecha de publicación:
Fecha Ahead of Print:
Autores de ISABIAL
Participantes ajenos a ISABIAL
- Sánchez-Pujol, J
Grupos de Investigación
Abstract
Objective Some reports suggest monosodium urate (MSU) crystals may deposit in artery walls. This exploratory study evaluated the capacity of optical coherence tomography (OCT) to detect MSU crystals in vessel phantoms.Methods We used 3D-printed blood vessel phantoms made of photosensitive acrylic resins, with varying compliances. 0.1cc volume injections of centrifugated human synovial fluids containing MSU crystals, calcium pyrophosphate crystals or 0.9% saline were performed in four predefined locations in the phantoms. OCT was subsequently performed in a blinded manner by two cardiologists, experts in the technique. Two exploratory definitions for MSU crystal deposits were used, depicting a lesion with high attenuation (#1) or also with a linear morphology (#2). Diagnostic properties of both definitions were studied building 2x2 tables.Results Definition #1 was found by OCT in 3/8 (37.5%) of MSU injections and in 3/16 (18.8%) of controls, what yielded a sensitivity of 37.5%, specificity of 81.3%, positive and predictive values of 50.0% and 72.2% respectively, and positive and negative likelihood ratios of 2 and 0.77. Definition #2 was only seen in 2 cases, both with MSU crystals (8.3%); this definition showed a sensitivity of 25.0%, specificity of 100%, positive and predictive values of 100.0% and 72.7%, a negative likelihood ratio of 0.8, while the positive ratio could not be calculated. Data seemed to be slightly better with Semirigid phantoms.Conclusion This preliminary, preclinical data suggest OCT could detect MSU crystals deposits in vessel walls.
Copyright: © 2025 Sánchez-Pujol et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Datos de la publicación
Documentos
Filiaciones
Proyectos y Estudios Clínicos
IDENTIFICACIÓN DE CRISTALES DE URATO MONOSÓDICO MEDIANTE TOMOGRAFÍA DE COHERENCIA ÓPTICA (OCT) CORONARIA: UN ESTUDIO EXPLORATORIO
Investigador Principal: MARIANO NICOLAS ANDRES COLLADO
UGP-20-086 . 2020
Cita
Sánchez Pujol J, Valencia J, Ruiz Nodar JM, Andres M. Could optical coherence tomography detect monosodium urate crystal deposition at artery walls? An exploratory, phantom-based study. PLoS One. 03 abril 2025;20(4):e0320742. https://doi.org/10.1371/journal.pone.0320742.
Portal de investigación