Can ICD Electrograms Help Ventricular Tachycardia Ablation? Results From the Multicenter Randomized AIDEG-VTA Trial
Fecha de publicación:
Fecha Ahead of Print:
Autores de ISABIAL
Participantes ajenos a ISABIAL
- Ortiz, M
- García-Fernández, J
- Martínez-Alday, JD
- Font, ER
- Moreno, J
- López, MA
- Almor, JM
- Gil, ML
- Medina, DG
- Granell, RR
- Peinado, RP
- Gelizo, VB
- Muñoz, JJS
- Medina, O
- Díaz-Parreño, SA
- Gonzalez, JM
- Merodio, JMO
- Almendral, J
Grupos de Investigación
Abstract
BACKGROUND The results of ablation of sustained monomorphic ventricular tachycardia (SMVT) are suboptimal. For many patients with implantable cardioverter-defibrillators (ICDs), ICD electrograms (ICD-EGs) provide the only available information on SMVT. ICD-EGs have the ability to distinguish morphologically distinct SMVT and can be used for pace mapping. OBJECTIVES This study aimed to evaluate whether using ICD-EG information during an ablation procedure influences outcomes. METHODS Patients with structural heart disease and SMVT documented by an ICD-EG, undergoing ablation, were randomly assigned in a 1:1 ratio to either an ablation incorporating ICD-EG data during the procedure (intervention group) or to conventional ablation. The ICD-EG obtained during induced SMVT and pace mapping was compared to ICD-EG from spontaneous SMVT to target the "clinical" SMVT for ablation. Ablation could be performed during SMVT (if tolerated), during sinus rhythm ("substrate ablation"), or both. RESULTS A total of 15 centers randomized 260 patients. Characterization of induced SMVT as clinical/nonclinical and pace mapping were more frequent in the intervention group. Most patients underwent pure substrate ablation (65%), with complementary ablation during SMVT in 26%, showing no significant difference between groups. No differences were found in acute efficacy. In the intention-to-treat analysis, the primary endpoint of SMVT recurrence within 6 months postablation occurred in 46 (36%) patients in the intervention group and 59 (46%) in the conventional group (HR: 0.73; 95% CI: 0.49-1.07; P = 0.11). In the per-protocol analysis, SMVT recurrence at 6 months postablation reached statistical significance (HR: 0.66; 95% CI: 0.44-0.99; P = 0.045). During the entire follow-up period (44 f 29 months), SMVT recurrence occurred in 67% and 76% (HR: 0.80; 95% CI: 0.60-1.08; P = 0.14). The number of SMVT episodes was significantly lower in the intervention group (HR: 0.45; 95% CI: 0.24-0.84; P = 0.013), as was the rate of electrical storm (23% vs 41%; HR: 0.54; 95% CI: 0.34-0.85; P = 0.007). There were no differences in ICD shocks. CONCLUSIONS In patients with structural heart disease and ICD-documented SMVT, using ICD-EG information during the ablation procedure to focalize ablation toward the clinical ventricular tachycardia is associated with a nonsignificant decrease in SMVT recurrence rate, a significant reduction in the number of ventricular tachycardia episodes, and a lower rate of arrhythmic storm. (JACC. 2025;85:1124-1137) (c) 2025 by the American College of Cardiology Foundation.
Copyright © 2025 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Datos de la publicación
Documentos
Filiaciones
Keywords
- ablation; electrical storm; electrogram; implantable cardioverter- defibrillator; ventricular tachycardia
Cita
Criado J, Ortiz M, García Fernández J, Martínez Alday JD, Font ER, Moreno J, López MA et al. Can ICD Electrograms Help Ventricular Tachycardia Ablation? Results From the Multicenter Randomized AIDEG-VTA Trial. J. Am. Coll. Cardiol. 25 marzo 2025;85(11):https://doi.org/10.1016/j.jacc.2024.10.104.
Portal de investigación